CEMENT BASED



PATCHING
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONPATCH 300
Cosmetic repair mortar for minor surface defects on concrete & mortar.
For surface blemish repairs such as blow holes or bug outs.
Approx. 1.8 kg/m2/mm thickness
CONPATCH 600
A fine high strength, one part, polymer modified, fibre reinforced repair mortar.
For concrete repairs where fine structural repair material is required.
Approx. 2 kg/m2/mm thickness
CONPATCH 600HS
One part polymer modified very high strength structural repair mortar
For concrete repairs where a fine very high strength structural repair material is required
2.20-2.30 kg/m2/mm thickness
CONPATCH 600MCI
One part polymer modified fine concrete repair mortar incorporating a corrosion inhibitor
For concrete repairs where a fine structural repair material is required with incorporation of a corrosion inhibitor.
Approx. 2 kg/m2/mm thickness
CONPATCH 635
One part polymer modified, medium weight repair mortar.
For medium build repair work up to 40 mm overhead.
Approx. 1.6 kg/m2/mm thickness
CONPATCH 675
One part light weight, polymer modified, fibre reinforced, high build, non-slumping repair mortar.
For overhead non-structural repair work. One layer up to 80 mm+.
Approx. 1.4 kg/m2/mm thickness
POURING PUMPING & FORMING
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONPATCH MC
High strength, shrinkage compensated free flowing micro concrete.
Use in large volume concrete repair sections both vertical & horizontal. Void filling, pile cap & difficult access repairs.
Approx. 77-78 x 25 kg bags will yield 1 m3 of grout depending on water content.
CONGROUT FR
A precision non-shrink cementitious grout with corrosion & fire resistance properties.
Used under machine base plates, bridge bearings and all areas repairing precision grouting with corrosion & fire resistance.
76 x 25 kg bags & 285 litres of water for approx. 1 m3 of mortar.
CONGROUT 1000
Non shrink, pre-mixed, cementitious fine precision grout for gaps down to 5 mm.
For grouting narrow gaps under machine base plates, columns, crane rails, bridge bearings etc.
74-78 x 25 kg bags for approx. 1m3 of grout depending on water content.
CONGROUT RES
Very rapid early strength, non shrink cementitious precision grout.
For use where early loading is required, 25 N/mm2 at approx. 2 hours. 40-50 N/mm2 at 6-8 hours.
74-75 x 25 kg bags +294 ltr of water for approx. 1m3 of grout for fluid consistency. 72-74 x 25 kg bags +243.6 ltr of water for approx. 1m3 of grout for pourable consistency.
SPRAYING
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONPATCH GC
A premixed, prebagged one component cementitious shotcrete for concrete repair.
Use in large repairs of concrete structures such as bridges, jettys, wharves, fly overs, building fecades, columns & soffits.
Approx. 2.1 kg/m2/mm thickness
CONPATCH 600MCI
One part polymer modified fine concrete repair mortar incorporating a corrosion inhibitor
For concrete repairs where a fine structural repair material is required with incorporation of corrosion inhibitor.
Approx. 2 kg/m2/mm thickness
CONPATCH 600HS
One part polymer modified very high strength structural repair mortar
For concrete repairs where a fine very high strength structural repair material is required
2.20-2.30 kg/m2/mm thickness
UNDERWATER
DESIGNATION
DESCRIPTION
PRINCIPLE USES
COVERAGE / YIELD
TDS
CONGROUT UWG
A non-shrink cement based grout for underwater applications.
Design for use in underwater or tidal zones such as bridge & quay columns, concrete piling. slipways, dams & other underwater structures.
Approx. 67-70 bag x 25 kg for approx 1 m3 grout depending on water content.
Cement Based



PATCHING
DESIGNATION : CONPATCH 300
DESCRIPTION : Cosmetic repair mortar for minor surface defects on concrete & mortar.
PRINCIPLE USES : For surface blemish repairs such as blow holes or bug outs.
COVERAGE / YIELD : Approx. 1.8 kg/m2/mm thickness
DESIGNATION : CONPATCH 600
DESCRIPTION : A fine high strength, one part, polymer modified, fibre reinforced repair mortar.
PRINCIPLE USES : For concrete repairs where fine structural repair material is required.
COVERAGE / YIELD : Approx. 2 kg/m2/mm thickness
DESIGNATION : CONPATCH 600HS
DESCRIPTION : One part polymer modified very high strength structural repair mortar
PRINCIPLE USES : For concrete repairs where a fine very high strength structural repair material is required
COVERAGE / YIELD : 2.20-2.30 kg/m2/mm thickness
DESIGNATION : CONPATCH 600MCI
DESCRIPTION : One part polymer modified fine concrete repair mortar incorporating a corrosion inhibitor
PRINCIPLE USES : For concrete repairs where a fine structural repair material is required with incorporation of corrosion inhibitor.
COVERAGE / YIELD : Approx. 2 kg/m2/mm thickness
DESIGNATION : CONPATCH 635
DESCRIPTION : One part polymer modified, medium weight repair mortar.
PRINCIPLE USES : For medium build repair work up to 40 mm overhead.
COVERAGE / YIELD : Approx. 1.6 kg/m2/mm thickness
DESIGNATION : CONPATCH 675
DESCRIPTION : One part light weight, polymer modified, fibre reinforced, high build, non-slumping repair mortar.
PRINCIPLE USES : For overhead non-structural repair work. One layer up to 80 mm+.
COVERAGE / YIELD : Approx. 1.4 kg/m2/mm thickness
POURING PUMPING & FORMING
DESIGNATION : CONPATCH MC
DESCRIPTION : High strength, shrinkage compensated free flowing micro concrete.
PRINCIPLE USES : Use in large volume concrete repair sections both vertical & horizontal. Void filling, pile cap & difficult access repairs.
COVERAGE / YIELD : Approx. 77-78 x 25 kg bags will yield 1 m3 of grout depending on water content.
DESIGNATION : CONGROUT FR
DESCRIPTION : A precision non-shrink cementitious grout with corrosion & fire resistance properties.
PRINCIPLE USES : Used under machine base plates, bridge bearings and all areas repairing precision grouting with corrosion & fire resistance.
COVERAGE / YIELD : 76 x 25 kg bags & 285 litres of water for approx. 1 m2 of mortar.
DESIGNATION : CONGROUT 1000
DESCRIPTION : Non shrink, pre-mixed, cementitious fine precision grout for gaps down to 5 mm.
PRINCIPLE USES : For grouting narrow gaps under machine base plates, columns, crane rails, bridge bearings etc
COVERAGE / YIELD : 74-78 x 25 kg bags for approx. 1m3 of grout depending on water content.
DESIGNATION : CONGROUT RES
DESCRIPTION : Very rapid early strength, non shrink cementitious precision grout
PRINCIPLE USES : For use where early loading is required, 25 N/mm2 at approx. 2 hours. 40-50 N/mm2 at 6-8 hours.
COVERAGE / YIELD : 74-75 x 25 kg bags +294 ltr of water for approx. 1m3 of grout for fluid consistency. 72-74 x 25 kg bags +243.6 ltr of water for approx. 1m3 of grout for pourable consistency.
SPRAYING
DESIGNATION : CONPATCH GC
DESCRIPTION : A premixed, prebagged one component cementitious shotcrete for concrete repair.
PRINCIPLE USES : Use in large repairs of concrete structures such as bridges, jettys, wharves, fly overs, building fecades, columns & soffits.
COVERAGE / YIELD : Approx. 2.1 kg/m2/mm thickness
DESIGNATION : CONPATCH 600MCI
DESCRIPTION : One part polymer modified fine concrete repair mortar incorporating a corrosion inhibitor
PRINCIPLE USES : For concrete repairs where a fine structural repair material is required with incorporation of corrosion inhibitor.
COVERAGE / YIELD : Approx. 2 kg/m2/mm thickness
DESIGNATION : CONPATCH 600HS
DESCRIPTION : One part polymer modified very high strength structural repair mortar
PRINCIPLE USES : For concrete repairs where a fine very high strength structural repair material is required
COVERAGE / YIELD : 2.20-2.30 kg/m2/mm thickness
UNDER WATER
DESIGNATION : CONGROUT UWG
DESCRIPTION : A non-shrink cement based grout for underwater applications.
PRINCIPLE USES : Design for use in underwater or tidal zones such as bridge & quay columns, concrete piling. slipways, dams & other underwater structures.
COVERAGE / YIELD : Approx. 67-70 bag x 25 kg for approx 1 m3 grout depending on water content.